Electric Pole Accessories

CWC-2PRXP: Drop Wire Clamp 1-2 Pair

The CWC-2PRXP 1–2 pair drop wire clamp supports telephone drop wire at compatible span clamps, drive hooks and other drop attachments. Its plastic shim forms part of the compression grip; specify your cable dimensions and preferred clamp material to confirm the right configuration.

CWC-2PRXP: Drop Wire Clamp 1-2 Pair

The CWC-2PRXP 1–2 pair drop wire clamp supports telephone drop wire at compatible span clamps, drive hooks and other drop attachments. Its plastic shim forms part of the compression grip; specify your cable dimensions and preferred clamp material to confirm the right configuration.

1–2 Pair Drop Wire Clamp with Plastic Shim

The CWC-2PRXP drop wire clamp supports one- and two-pair telephone drop wire at compatible span clamps, drive hooks and other drop attachments. Its shell, wedge and non-metallic plastic shim hold the wire by compression.

Choose this model for review when your purchasing specification calls for a plastic shim rather than a metal shim. Before ordering, match your wire dimensions, clamp material and attachment arrangement to the intended installation.

Product Specifications

Item Specification
Model CWC-2PRXP
Product Drop Wire Clamp 1–2 Pair with Plastic Shim
Primary application One- and two-pair telephone drop wire
Listed clamp material options Aluminum 5052, stainless steel 201 or stainless steel 304; confirm the component configuration when ordering
Tail wire 201/304 stainless steel; specify the required grade
Shim type Plastic (non-metallic)
Attachment points Compatible span clamps, drive hooks and other drop attachments

Published holding requirement: the clamp is specified to hold suitable drop wire without slippage until the wire breaks or a maximum test load of 555 lb is reached. This is not a stated safe working load. Confirm the cable, clamp configuration and applicable test conditions for your project.

Drop Wire Clamp 1-2 Pair

Product Advantages

  • Non-metallic shim: the plastic insert distinguishes this model from clamps using metal shims and gives you a clearly defined contact component to specify.
  • Compression assembly: the shell, shim and wedge work together to grip compatible drop wire.
  • Material selection: Aluminum 5052, SS201 and SS304 are listed for the clamp. Specify the required option and confirm which components it covers.
  • Stainless steel tail wire: the tail wire is formed from 201/304 stainless steel for connection to compatible drop attachments.
  • Defined telephone application: the 1–2 pair designation helps you identify the intended service-drop category before checking dimensional fit.

Applications and Selection

Use the CWC-2PRXP for compatible one- and two-pair aerial telephone drop wires at supporting fittings. It is relevant to new service-drop installations and replacement work where the cable and attachment hardware match the clamp.

Pair count alone does not determine fit. Provide your wire width and thickness or diameter, jacket material and construction drawing. Also identify the support fitting and required service load.

For a fiber optic or FTTH application, request a separate compatibility review. The telephone-wire description and 555 lb holding requirement do not establish optical performance or suitability for every fiber drop cable.

Installation Considerations

Request the assembly drawing for your CWC-2PRXP configuration before installation. Confirm the wire position, plastic shim orientation, wedge engagement and tail-wire connection against the approved instructions.

Check that your support fitting and cable meet the installation requirements. Establish allowable tension and span conditions for your project; do not use the published test-load ceiling as the installation tension.

Aerial Drop Wire Clamp

The linked video provides general drop wire clamp context. Confirm the model-specific procedure for your cable and clamp configuration.

Supply from Hbcrownwealth

Hbcrownwealth manufactures and supplies hardware for overhead power and telecommunications systems. For wholesale procurement, identify CWC-2PRXP and the plastic shim in your inquiry so the requested configuration is clear.

You can compare our drop wire clamp range and source related aerial drop hardware. Include any sample, material documentation, inspection or customization requirements for review with your order specification.

Frequently Asked Questions

What is the CWC-2PRXP used for?

It supports compatible one- and two-pair telephone drop wire at span clamps, drive hooks and other drop attachments. Confirm the wire dimensions and attachment fit before selection.

What type of shim does this clamp have?

The CWC-2PRXP has a plastic, non-metallic shim. State this requirement when ordering so it is not confused with a metal-shim clamp. The plastic shim does not by itself establish an electrical insulation rating for the assembly.

Which materials can I specify?

The listed clamp materials are Aluminum 5052, stainless steel 201 and stainless steel 304. The tail wire is described separately as 201/304 stainless steel. Confirm the selected grade and the material of each component in your purchase specification.

Does 555 lb mean the safe working load?

No. The published requirement describes holding suitable drop wire without slippage until wire breakage or a maximum test load of 555 lb. A permitted working load and any required safety factor must be confirmed for the actual cable and installation.

Can I use this model for FTTH fiber drop cable?

Fiber cable compatibility requires separate confirmation. Send your cable cross-section, dimensions and optical performance requirements. Do not assume the telephone-wire holding requirement also verifies fiber cable performance.

What information is needed for a quotation?

Provide model CWC-2PRXP, cable dimensions or a drawing, material preference, quantity and delivery destination. Include the required load, support fitting and any inspection or packing requirements so your quotation covers the intended configuration.

Aerial Drop Wire Clamp

Request a CWC-2PRXP Quotation

Contact Hbcrownwealth with your drop wire specification and order quantity. Specify the plastic shim and required material option when requesting pricing for your 1–2 pair drop wire clamp.

Item Specification
Model CWC-2PRXP
Product Drop Wire Clamp 1–2 Pair with Plastic Shim
Primary application One- and two-pair telephone drop wire
Listed clamp material options Aluminum 5052, stainless steel 201 or stainless steel 304; confirm the component configuration when ordering
Tail wire 201/304 stainless steel; specify the required grade
Shim type Plastic (non-metallic)
Attachment points Compatible span clamps, drive hooks and other drop attachments

Published holding requirement: the clamp is specified to hold suitable drop wire without slippage until the wire breaks or a maximum test load of 555 lb is reached. This is not a stated safe working load. Confirm the cable, clamp configuration and applicable test conditions for your project.

1–2 Pair Drop Wire Clamp with Plastic Shim

The CWC-2PRXP drop wire clamp supports one- and two-pair telephone drop wire at compatible span clamps, drive hooks and other drop attachments. Its shell, wedge and non-metallic plastic shim hold the wire by compression.

Choose this model for review when your purchasing specification calls for a plastic shim rather than a metal shim. Before ordering, match your wire dimensions, clamp material and attachment arrangement to the intended installation.

Product Specifications

Item Specification
Model CWC-2PRXP
Product Drop Wire Clamp 1–2 Pair with Plastic Shim
Primary application One- and two-pair telephone drop wire
Listed clamp material options Aluminum 5052, stainless steel 201 or stainless steel 304; confirm the component configuration when ordering
Tail wire 201/304 stainless steel; specify the required grade
Shim type Plastic (non-metallic)
Attachment points Compatible span clamps, drive hooks and other drop attachments

Published holding requirement: the clamp is specified to hold suitable drop wire without slippage until the wire breaks or a maximum test load of 555 lb is reached. This is not a stated safe working load. Confirm the cable, clamp configuration and applicable test conditions for your project.

Drop Wire Clamp 1-2 Pair

Product Advantages

  • Non-metallic shim: the plastic insert distinguishes this model from clamps using metal shims and gives you a clearly defined contact component to specify.
  • Compression assembly: the shell, shim and wedge work together to grip compatible drop wire.
  • Material selection: Aluminum 5052, SS201 and SS304 are listed for the clamp. Specify the required option and confirm which components it covers.
  • Stainless steel tail wire: the tail wire is formed from 201/304 stainless steel for connection to compatible drop attachments.
  • Defined telephone application: the 1–2 pair designation helps you identify the intended service-drop category before checking dimensional fit.

Applications and Selection

Use the CWC-2PRXP for compatible one- and two-pair aerial telephone drop wires at supporting fittings. It is relevant to new service-drop installations and replacement work where the cable and attachment hardware match the clamp.

Pair count alone does not determine fit. Provide your wire width and thickness or diameter, jacket material and construction drawing. Also identify the support fitting and required service load.

For a fiber optic or FTTH application, request a separate compatibility review. The telephone-wire description and 555 lb holding requirement do not establish optical performance or suitability for every fiber drop cable.

Installation Considerations

Request the assembly drawing for your CWC-2PRXP configuration before installation. Confirm the wire position, plastic shim orientation, wedge engagement and tail-wire connection against the approved instructions.

Check that your support fitting and cable meet the installation requirements. Establish allowable tension and span conditions for your project; do not use the published test-load ceiling as the installation tension.

Aerial Drop Wire Clamp

The linked video provides general drop wire clamp context. Confirm the model-specific procedure for your cable and clamp configuration.

Supply from Hbcrownwealth

Hbcrownwealth manufactures and supplies hardware for overhead power and telecommunications systems. For wholesale procurement, identify CWC-2PRXP and the plastic shim in your inquiry so the requested configuration is clear.

You can compare our drop wire clamp range and source related aerial drop hardware. Include any sample, material documentation, inspection or customization requirements for review with your order specification.

Frequently Asked Questions

What is the CWC-2PRXP used for?

It supports compatible one- and two-pair telephone drop wire at span clamps, drive hooks and other drop attachments. Confirm the wire dimensions and attachment fit before selection.

What type of shim does this clamp have?

The CWC-2PRXP has a plastic, non-metallic shim. State this requirement when ordering so it is not confused with a metal-shim clamp. The plastic shim does not by itself establish an electrical insulation rating for the assembly.

Which materials can I specify?

The listed clamp materials are Aluminum 5052, stainless steel 201 and stainless steel 304. The tail wire is described separately as 201/304 stainless steel. Confirm the selected grade and the material of each component in your purchase specification.

Does 555 lb mean the safe working load?

No. The published requirement describes holding suitable drop wire without slippage until wire breakage or a maximum test load of 555 lb. A permitted working load and any required safety factor must be confirmed for the actual cable and installation.

Can I use this model for FTTH fiber drop cable?

Fiber cable compatibility requires separate confirmation. Send your cable cross-section, dimensions and optical performance requirements. Do not assume the telephone-wire holding requirement also verifies fiber cable performance.

What information is needed for a quotation?

Provide model CWC-2PRXP, cable dimensions or a drawing, material preference, quantity and delivery destination. Include the required load, support fitting and any inspection or packing requirements so your quotation covers the intended configuration.

Aerial Drop Wire Clamp

Request a CWC-2PRXP Quotation

Contact Hbcrownwealth with your drop wire specification and order quantity. Specify the plastic shim and required material option when requesting pricing for your 1–2 pair drop wire clamp.

Item Specification
Model CWC-2PRXP
Product Drop Wire Clamp 1–2 Pair with Plastic Shim
Primary application One- and two-pair telephone drop wire
Listed clamp material options Aluminum 5052, stainless steel 201 or stainless steel 304; confirm the component configuration when ordering
Tail wire 201/304 stainless steel; specify the required grade
Shim type Plastic (non-metallic)
Attachment points Compatible span clamps, drive hooks and other drop attachments

Published holding requirement: the clamp is specified to hold suitable drop wire without slippage until the wire breaks or a maximum test load of 555 lb is reached. This is not a stated safe working load. Confirm the cable, clamp configuration and applicable test conditions for your project.