Electric Pole Accessories

CW-PA50 Plastic Tension Clamp with Bail Retaining Clip

The CW-PA50 plastic tension clamp is specified for 50–70 mm² conductor cross-sections and 11.2–12.8 mm messenger diameters, with a 6 kN breaking load.

Its mechanically strong, weather-resistant insulating body includes a bail retaining clip designed to prevent the bail from slipping out. Send Hbcrownwealth your cable drawing, attachment requirements and quantity to confirm compatibility and receive a quotation.

CW-PA50 Plastic Tension Clamp with Bail Retaining Clip

The CW-PA50 plastic tension clamp is specified for 50–70 mm² conductor cross-sections and 11.2–12.8 mm messenger diameters, with a 6 kN breaking load.

Its mechanically strong, weather-resistant insulating body includes a bail retaining clip designed to prevent the bail from slipping out. Send Hbcrownwealth your cable drawing, attachment requirements and quantity to confirm compatibility and receive a quotation.

Product Specifications

The CW-PA50 plastic tension clamp is an overhead cable anchoring component with a dedicated clip for retaining the bail in the body. When selecting this model, review the cable dimensions, attachment arrangement and mechanical requirements together.

Specification CW-PA50
Product type Plastic tension clamp
Body Mechanically strong, weather-resistant insulating material
Bail retention Clip designed to prevent the bail from slipping out of the body
Breaking load 6 kN
Standard reference NFC33-042
Conductor cross-section 50–70 mm²
Messenger diameter 11.2–12.8 mm

Cable sizing: the specified conductor cross-section is 50–70 mm², and the messenger diameter is 11.2–12.8 mm. Check both against your cable drawing, including the construction of the member that will be gripped.

Mechanical rating: the 6 kN specification is a breaking load. It does not define the allowable working load, installation tension or permitted span of your cable assembly.

Product Advantages

Dedicated Bail Retaining Clip

The specially designed clip helps prevent the bail from slipping out of the clamp body. This feature addresses retention at the bail-to-body connection. Check that the clip is present and correctly engaged as part of your assembly inspection.

Mechanically Strong Insulating Body

The body uses insulating material specified for high mechanical strength. For procurement, assess this construction alongside cable fit and the required load performance. The insulating body does not, by itself, establish a voltage rating for the complete installation.

Weather-Resistant Construction

The body material is described as weather-resistant for outdoor hardware use. If your project requires a particular UV test, temperature range or exposure classification, include those criteria in your inquiry so suitability and documentation can be reviewed.

6 kN Breaking-Load Specification

The stated breaking load provides a mechanical reference for technical review. Use it alongside the cable and support specifications; your project designer must determine the allowable service load and applicable design margin.

Applications and Selection

Consider CW-PA50 for compatible overhead cable anchoring arrangements where the cable, clamp and support fitting meet your project requirements. The bail connection and retaining clip should be evaluated as part of the complete attachment assembly.

  • New cable installations: provide the cable construction, conductor cross-section and messenger outside diameter for model selection.
  • Replacement projects: compare the existing clamp, attachment geometry and cable dimensions before approving a substitute.
  • Project and wholesale supply: identify each cable type and its required clamp separately in your purchasing schedule.

Do not treat conductor cross-section in mm² as equivalent to outside diameter in mm. Insulation, construction and the member being gripped also affect compatibility. For ABC, telecom or other cable systems, submit the actual cable drawing rather than relying on the application name alone.

Installation Planning and Inspection

Obtain the fitting instructions for the exact CW-PA50 and cable combination before installation. Use the following checklist to prepare your work and acceptance requirements:

  1. Confirm cable fit. Check the approved cable range against the conductor and messenger dimensions in your drawing.
  2. Check the support connection. Confirm that the bail and support fitting have compatible geometry and meet the project load requirements.
  3. Inspect the retaining clip. Verify that the clip and body are undamaged and confirm the correct engagement method from the fitting instructions.
  4. Follow the approved installation procedure. Use the specified cable positioning, tensioning method and tools.
  5. Inspect the completed assembly. Check bail retention, attachment security and the condition of the cable under the applicable acceptance procedure.

The published information does not specify torque, span length, tool requirements or installation tension. Confirm these details for your assembly; do not use 6 kN as the installation tension.

CW-PA50: Plastic Tension Clamp

Why Choose Hbcrownwealth?

Hbcrownwealth is a manufacturer, supplier and wholesaler of overhead hardware for power and telecommunications systems. For CW-PA50 purchasing, send your cable specification and attachment requirements so the quotation can identify the proposed configuration clearly.

Specify any required material documentation, dimensional acceptance criteria and mechanical test reports before ordering. Include the required edition of NFC33-042 if your project uses that reference, and confirm the availability and scope of supporting documents.

Custom Requirements and Order Planning

For an OEM/ODM inquiry, provide drawings and describe the changes you need. Model-specific customization, samples, MOQ and lead time require confirmation. For repeat orders, reference the previously approved configuration as well as the CW-PA50 model name.

Frequently Asked Questions

1. What distinguishes the CW-PA50 plastic tension clamp?

Its defining listed feature is a clip designed to prevent the bail from slipping out of the body. The clamp also has a weather-resistant insulating body and a published breaking load of 6 kN.

2. What conductor cross-section and messenger diameter does it accept?

The specified ranges are 50–70 mm² conductor cross-section and 11.2–12.8 mm messenger diameter. These describe different dimensions; check both against your cable drawing and insulation construction before ordering.

3. What does the bail retaining clip do?

The clip is designed to retain the bail in the clamp body. It does not replace the need to check the support connection, cable fit and correct assembly under the fitting instructions.

4. Is 6 kN the allowable working load?

No. The published 6 kN value is a breaking load. Allowable working load and installation tension must be established separately for the complete cable, clamp and anchorage assembly.

5. What are the body and bail made from?

The body is specified as mechanically strong, weather-resistant insulating material. The published description does not identify the bail material or finish. Request confirmation if your project requires a particular metal grade or coating.

6. Is the clamp suitable for outdoor use or UV exposure?

The body material is described as weather-resistant, but a specific UV rating or temperature range is not stated. Provide your environmental and test requirements so the proposed supply can be assessed for the installation conditions.

7. Is NFC33-042 certification supplied with the clamp?

NFC33-042 is listed as a standard reference; that alone does not establish certification. Specify any required certificate, test report and standard edition so document availability and applicability can be confirmed.

8. What information is needed for a bulk or customized quotation?

Provide CW-PA50, quantity, cable construction, conductor cross-section, messenger diameter and attachment details. Add the environment, required mechanical performance and documents. For custom supply, include your drawing and requested changes for feasibility review.

Request a CW-PA50 Quotation

Use the inquiry form below to send Hbcrownwealth your cable drawing, support-fitting details and purchasing quantity. Confirm the cable range and required acceptance documents before placing the order.

If you are comparing messenger-wire clamps, review the CW-PA39 cable tension clamp specifications separately. Its listed 2.5 kN breaking load differs from CW-PA50’s 6 kN rating, and the models should not be treated as interchangeable without a compatibility review.

CW-PA50 Technical Parameters

Specification CW-PA50
Product type Plastic tension clamp
Body Mechanically strong, weather-resistant insulating material
Bail retention Clip designed to prevent the bail from slipping out of the body
Breaking load 6 kN
Standard reference NFC33-042
Conductor cross-section 50–70 mm²
Messenger diameter 11.2–12.8 mm

The 50–70 mm² value is conductor cross-section; 11.2–12.8 mm is messenger diameter. Check both against your cable construction and the member being gripped.

Breaking load is not an allowable working load or installation tension. Confirm the required NFC33-042 edition and supporting documents when specifying your order.

Product Specifications

The CW-PA50 plastic tension clamp is an overhead cable anchoring component with a dedicated clip for retaining the bail in the body. When selecting this model, review the cable dimensions, attachment arrangement and mechanical requirements together.

Specification CW-PA50
Product type Plastic tension clamp
Body Mechanically strong, weather-resistant insulating material
Bail retention Clip designed to prevent the bail from slipping out of the body
Breaking load 6 kN
Standard reference NFC33-042
Conductor cross-section 50–70 mm²
Messenger diameter 11.2–12.8 mm

Cable sizing: the specified conductor cross-section is 50–70 mm², and the messenger diameter is 11.2–12.8 mm. Check both against your cable drawing, including the construction of the member that will be gripped.

Mechanical rating: the 6 kN specification is a breaking load. It does not define the allowable working load, installation tension or permitted span of your cable assembly.

Product Advantages

Dedicated Bail Retaining Clip

The specially designed clip helps prevent the bail from slipping out of the clamp body. This feature addresses retention at the bail-to-body connection. Check that the clip is present and correctly engaged as part of your assembly inspection.

Mechanically Strong Insulating Body

The body uses insulating material specified for high mechanical strength. For procurement, assess this construction alongside cable fit and the required load performance. The insulating body does not, by itself, establish a voltage rating for the complete installation.

Weather-Resistant Construction

The body material is described as weather-resistant for outdoor hardware use. If your project requires a particular UV test, temperature range or exposure classification, include those criteria in your inquiry so suitability and documentation can be reviewed.

6 kN Breaking-Load Specification

The stated breaking load provides a mechanical reference for technical review. Use it alongside the cable and support specifications; your project designer must determine the allowable service load and applicable design margin.

Applications and Selection

Consider CW-PA50 for compatible overhead cable anchoring arrangements where the cable, clamp and support fitting meet your project requirements. The bail connection and retaining clip should be evaluated as part of the complete attachment assembly.

  • New cable installations: provide the cable construction, conductor cross-section and messenger outside diameter for model selection.
  • Replacement projects: compare the existing clamp, attachment geometry and cable dimensions before approving a substitute.
  • Project and wholesale supply: identify each cable type and its required clamp separately in your purchasing schedule.

Do not treat conductor cross-section in mm² as equivalent to outside diameter in mm. Insulation, construction and the member being gripped also affect compatibility. For ABC, telecom or other cable systems, submit the actual cable drawing rather than relying on the application name alone.

Installation Planning and Inspection

Obtain the fitting instructions for the exact CW-PA50 and cable combination before installation. Use the following checklist to prepare your work and acceptance requirements:

  1. Confirm cable fit. Check the approved cable range against the conductor and messenger dimensions in your drawing.
  2. Check the support connection. Confirm that the bail and support fitting have compatible geometry and meet the project load requirements.
  3. Inspect the retaining clip. Verify that the clip and body are undamaged and confirm the correct engagement method from the fitting instructions.
  4. Follow the approved installation procedure. Use the specified cable positioning, tensioning method and tools.
  5. Inspect the completed assembly. Check bail retention, attachment security and the condition of the cable under the applicable acceptance procedure.

The published information does not specify torque, span length, tool requirements or installation tension. Confirm these details for your assembly; do not use 6 kN as the installation tension.

CW-PA50: Plastic Tension Clamp

Why Choose Hbcrownwealth?

Hbcrownwealth is a manufacturer, supplier and wholesaler of overhead hardware for power and telecommunications systems. For CW-PA50 purchasing, send your cable specification and attachment requirements so the quotation can identify the proposed configuration clearly.

Specify any required material documentation, dimensional acceptance criteria and mechanical test reports before ordering. Include the required edition of NFC33-042 if your project uses that reference, and confirm the availability and scope of supporting documents.

Custom Requirements and Order Planning

For an OEM/ODM inquiry, provide drawings and describe the changes you need. Model-specific customization, samples, MOQ and lead time require confirmation. For repeat orders, reference the previously approved configuration as well as the CW-PA50 model name.

Frequently Asked Questions

1. What distinguishes the CW-PA50 plastic tension clamp?

Its defining listed feature is a clip designed to prevent the bail from slipping out of the body. The clamp also has a weather-resistant insulating body and a published breaking load of 6 kN.

2. What conductor cross-section and messenger diameter does it accept?

The specified ranges are 50–70 mm² conductor cross-section and 11.2–12.8 mm messenger diameter. These describe different dimensions; check both against your cable drawing and insulation construction before ordering.

3. What does the bail retaining clip do?

The clip is designed to retain the bail in the clamp body. It does not replace the need to check the support connection, cable fit and correct assembly under the fitting instructions.

4. Is 6 kN the allowable working load?

No. The published 6 kN value is a breaking load. Allowable working load and installation tension must be established separately for the complete cable, clamp and anchorage assembly.

5. What are the body and bail made from?

The body is specified as mechanically strong, weather-resistant insulating material. The published description does not identify the bail material or finish. Request confirmation if your project requires a particular metal grade or coating.

6. Is the clamp suitable for outdoor use or UV exposure?

The body material is described as weather-resistant, but a specific UV rating or temperature range is not stated. Provide your environmental and test requirements so the proposed supply can be assessed for the installation conditions.

7. Is NFC33-042 certification supplied with the clamp?

NFC33-042 is listed as a standard reference; that alone does not establish certification. Specify any required certificate, test report and standard edition so document availability and applicability can be confirmed.

8. What information is needed for a bulk or customized quotation?

Provide CW-PA50, quantity, cable construction, conductor cross-section, messenger diameter and attachment details. Add the environment, required mechanical performance and documents. For custom supply, include your drawing and requested changes for feasibility review.

Request a CW-PA50 Quotation

Use the inquiry form below to send Hbcrownwealth your cable drawing, support-fitting details and purchasing quantity. Confirm the cable range and required acceptance documents before placing the order.

If you are comparing messenger-wire clamps, review the CW-PA39 cable tension clamp specifications separately. Its listed 2.5 kN breaking load differs from CW-PA50’s 6 kN rating, and the models should not be treated as interchangeable without a compatibility review.

CW-PA50 Technical Parameters

Specification CW-PA50
Product type Plastic tension clamp
Body Mechanically strong, weather-resistant insulating material
Bail retention Clip designed to prevent the bail from slipping out of the body
Breaking load 6 kN
Standard reference NFC33-042
Conductor cross-section 50–70 mm²
Messenger diameter 11.2–12.8 mm

The 50–70 mm² value is conductor cross-section; 11.2–12.8 mm is messenger diameter. Check both against your cable construction and the member being gripped.

Breaking load is not an allowable working load or installation tension. Confirm the required NFC33-042 edition and supporting documents when specifying your order.